YECPS'S modular is integrated with breaker(fuse cutout),contactor switch,overload protector ,under-voltage protector ,open-phase protector,voltmeter,amperemeter,electric leakage protector and isolator.
YECPS'S modular is integrated with breaker(fuse cutout),contactor switch,overload protector ,under-voltage protector ,open-phase protector,voltmeter,amperemeter,electric leakage protector and isolator.
YECPS modular is integrated with breaker(fuse),contactor,overload protector,under-voltage protector,open-phase protector,voltmeter,amperemeter,electric leakage protector and isolator.The advanced MCU digital processing technology guarantees,high detecting accuracy and strong anti-interference capability.
Module Type MCU Technology Integrated 16a 45a 125a Other Control Switches for Electric Motor Protection.
Rated current: 0.2~125A
Pole: 3P:33(3P with 3P protection), 30(3P with no protection)
4P:44(4P with 4P protection), 43(4P with 3 protection) ,40(4P with no protection)
YECPS'S modular is integrated with breaker(fuse cutout),contactor switch,overload protector ,under-voltage protector ,open-phase protector,voltmeter,amperemeter,electric leakage protector and isolator. The advanced MCU digital processing technology guarantees High detecting accuracy and strong anti-interference capability.
1. Manual operate&remote control.
2. Panel digital display&electrical signal alarm.
3. Current coordinator¤t protector(long overload delay,short Short-circuit delay,instantaneous short circuit).
4. Open-phase protection,over-current protection, circuit blockage detection, locked-rotor detection, shunt trip, short circuit protection, under-current protection, over-voltage protection, under-voltage protection, electric leakage protection, three-phase unbalance protection, electric protection.
5. High detecting accuracy,display via LED screen,voltmeter&ere-meter.
6. Integrated with setting button,shift button,digital button, resetting button.
7. Adopting MCU-E2PROM Tech to realize setting Memory function.
8. Analyzable fault memory.
9. RS485 communications open system,intelligent management.
10. Optional module and accessory apply to diverse electric power system
Name | Content |
Product category | Control And Protection Switch |
Current rank | 45,125 |
Breaking capacity class | C=Basic |
Pole |
3P:33(3P with 3P protection), 30(3P with no protection) 4P:44(4P with 4P protection), 43(4P with 3 protection), 40(4P with no protection) |
Release mode | M=Start motor protection infrequentlyL=Distribution protection |
Rated current | 0.2A~125A |
Accessory |
Fk1=2NO+1NC+1 short circuit +1breakdown Fk2=2NO+2NC+1 transfer+1 short circuit +1breakdown Fk3=4NO+3NC+1 transfer+1 short circuit +1breakdown |
Control voltage | Q=AC400V,M=AV220V |
Additional function |
F=Fire protection; L=Electric leakage; G=Isolating function; T=Communication |
Controller mode | B=Digital Pipe, Y=LCD screen |
1. Centigrade scale -5℃~40℃,Average Temperature <=35℃
2. Altitude<=2000 meters.
3. Relative humidity should under 50% while the temperature reach 40℃.Relative humidity should under 90%while temperature is about 20℃.
4. Protection level:lp20.
5. Pollution degree:Level 3.
6. Installation:690V system Ⅲ;380V system Ⅳ;control circuit Ⅱ.
From June 6 to 9, 2023, the 48th Moscow International Power Electronics Exhibition (ELEKTRO) Pavilion opened its doors to the public, and One Two Thre...
Exhibition previewTime flies, after three years of anti-epidemic efforts, remarkable results have been achieved. This year, 2023, trade flows will vas...
First of all, Schneider's low-voltage products include circuit breakers, switches, contactors, relays, etc., which are basically world famous brands.S...
In the design of a dual power transfer switch, the most important is the current control module (TCM), because the current is not strong enough to mee...